 www..com
OZNRaO Transient/Surge Absorbers (Type D)
Straight Leads Cut Type (Bulk Type)
n Ratings and Characteristics
] Refer to bulk standard type part no. (P20-P34).
n Dimensions in mm (not to scale)
notes ] Dimension OLO: Conforms to each individual specification. ]] Dimension OTO: Conforms to each individual specification.
Crimped Leads Cut Type (Bulk Type)
n Ratings and Characteristics
] Refer to bulk standard type part no. (P20-P34).
n Dimensions in mm (not to scale)
notes ] Dimension OLO: Conforms to each individual specification. ]] Dimension OTO: Conforms to each individual specification. ]]] Resin extenyions : No resin brlow center of the hook.
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Taping Specifications for Automated Assembly (Straight Leads and Taping)
n Ratings and Characteristics
] Refer to bulk standard type part no. (P20-P34).
n Taping Dimensions in mm (not to scale) Type IaII
] Dimension OTO: Conforms to each individual specification.
Type IIIaIV
] Dimension OTO: Conforms to each individual specification.
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Taping Specifications for Automated Assembly (Crimped Leads and Taping)
n Ratings and Characteristics n Taping Dimensions in mm (not to scale) Type I
] Refer to bulk standard type part no. (P20-P34).
] Dimension OTO: Conforms to each individual specification.
Type II
] Dimension OTO: Conforms to each individual specification.
ERZV ERZV ERZV ERZV
V621 V681 V751 V821
ERZV ERZV ERZV
V911 V102 V112
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Application Note for UL, CSA and VDE Recognized Components
Note: Register " Standard Registration No." when registering as the safe standard part, because it isn't registered in "Panasonic Part No." Please contact us about VDE certification
n Related Standards
(Applicasion Standard)
Standard No.
Category
Title Across-The-Line, Antenna Coupling, and Line-By-Pass Capacitors for Radio and Television-Type Appliances
File No.
Varistor Voltage Range 5 7 9 10 14 20 5 7 9 10 14 20 5 7 9 10 14 20 Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series Series 200 200 200 200 200 200 82 82 82 82 82 82 200 200 200 200 200 200 to 470 to 510 to 510 to 1800 to 1800 to 1800 to 470 to 510 to 510 to 1800 to 1800 to 1800 to 470 to 510 to 510 to 1800 to 1800 to 1800
UL1414
FOWX2
E62674 Vol.5, 10
UL1449
XUHT2
Transient Voltage Surge Suppressors
E86821 Vol.1
CSA C22.2 No.1 Class 2221 01
Accessories and Parts for Electronic Products
l Varistor for Across-The-Line use as transient protection on 120 Vac nominal system
LR-92226
Note: For UL497B recognized ZNRs, contact our sales office or factory.
n Standard Registration No.] and Standard Part No.
Please contact us about VDE certification
Standard Registration No.] V]820U V]101U V]121U V]151U V]201U V]221U V]241U V]271U V]331U V]361U V]391U V]431U V]471U V]511U V]621U V]681U V]751U V]821U V]911U V]102U V]112U V]182U ERZV 11D820 ERZV 11D101 ERZV 11D121 ERZV 11D151 ERZV 11D201 ERZV 11D221 ERZV 11D241 ERZV 11D271 ERZV 11D331 ERZV 11D361 ERZV 11D391 ERZV 11D431 ERZV 11D471 ERZV 11D511 ERZV 11D621 ERZV 11D681 ERZV 11D751 ERZV 11D821 ERZV 11D911 ERZV 11D102 ERZV 11D112 ERZV10D182CS ERZV 11V820 ERZV 11V101 ERZV 11V121 ERZV 11V151 ERZV 11V201 ERZV 11V221 ERZV 11V241 ERZV 11V271 ERZV 11V331 ERZV 11V361 ERZV 11V391 ERZV 11V431 ERZV 11V471 ERZV 11V511 ERZV 11V621 ERZV 11V681 ERZV 11V751 ERZV 11V821 ERZV 11V911 ERZV 11V102 ERZV 11V112 ERZV14D182CS Panasonic Part No. ERZV@@D820 ERZV@@D101 ERZV@@D121 ERZV@@D151 ERZV@@D201 ERZV@@D221 ERZV@@D241 ERZV@@D271 ERZV@@D331 ERZV@@D361 ERZV@@D391 ERZV@@D431 ERZV@@D471 ERZV@@D511 ERZV@@D621 ERZV@@D681 ERZV@@D751 ERZV@@D821 ERZV@@D911 ERZV@@D102 ERZV@@D112 ERZV20D182 ERZV@@V820 ERZV@@V101 ERZV@@V121 ERZV@@V151 ERZV@@V201 ERZV@@V221 ERZV@@V241 ERZV@@V271 ERZV@@V331 ERZV@@V361 ERZV@@V391 ERZV@@V431 ERZV@@V471 ERZV@@V511 ERZV@@V621 ERZV@@V681 ERZV@@V751 ERZV@@V821 ERZV@@V911 ERZV@@V102 ERZV@@V112 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 (5,7,9,10,14,20 ( 7,9,10,14,20 ( 10,14,20 ( 10,14,20 ( 10,14,20 ( 10,14,20 ( 10,14,20 ( 10,14,20 ( 10,14,20 Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series) Series)
] UL : Type Designation CSA : Part Number
] :5series is blank, 7series is 7, 9series is 9, 10series is 10, 14series is 14, 20series is 20 11:Code for Element Size @@:Code for Taping/Packing and Symbol of Element Size For the product Part No. except the above, contact our sales office or factory.
www..com
OZNRaO Transient/Surge Absorbers (Type D)
n The AC Rated Voltage and Maximum Allowable Voltage
Stadard Registration
Maximum Allowable Voltage ACrms (V) 50 60 75 95 130 140 150 175 210 230 250 275 300 315 385 420 460 510 550 625 680 1000 DC (V) 65 85 100 125 170 180 200 225 270 300 320 350 385 410 505 560 615 670 745 825 895 1465 (Not (Not (Not (Not UL1414 application) application) application) application) 125 125 125 125 125 125 250 250 250 250 250 250 250 250 250 250 250 250
Rated Voltage (Vrms) UL1449 45 55 68 86 118 127 136 159 189 209 227 250 272 291 350 381 418 463 500 568 600 600 VDE CSA C22.2 No.1 (Class 2221 01) CECC 42 201 (Not application) (Not application) (Not application) (Not application) 118 127 136 159 189 209 ]It is the same with 227 the Maximum Allowable Voltage. 250 272 291 350 381 418 463 500 568 618 909
No.] V]820U V]101U V]121U V]151U V]201U V]221U V]241U V]271U V]331U V]361U V]391U V]431U V]471U V]511U V]621U V]681U V]751U V]821U V]911U V]102U V]112U V]182U
] UL : Type Designation CSA : Part Number VDE : Please contact us
]:5Series is blank, 7series is 7, 9series is 9, 10series is 10, 14series is 14, 20series is 20
n Application Notes
1) CSA regulate "Maximum Rating of Fuse" for using ZNR to "Audio, Video and Similer Electronic Equipment" as below Maximum Rating of Fuse Maximum Peak Current (A) 8/20 s, 1 time (A) 3 500 and under 5 Over 500 to 2000 and under 10 Over 2000 to 6000 and under Not Specified Over 6000 2) ORated VoltagesO are specified for UL/CSA recognized components besides Maximum Allowable Voltage because of conforming to the Standby Current specified in safety standards. In case of making an application to UL/CSA approval for equipment with ZNR, the maximum AC operating voltage of equipment shall be lower than the ZNR Rated Voltage.
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Marking Contents and Packaging Specifications
] Please contact us about VDE certification n Marking Contents
n Explanation of the contents
V Trade Mark
]
111
V
]
111U CSA UL Monogram Recognized Components Mark
M Factory Identification Marking
None E Japan E Japan S G ESingapore
Abbreviation of Part No.
Registration No.
111ENominal Type Designation Varistor Voltage Part Number
Year Code and Monthly Code of the production E 1999:9,2000:0,2001:A 2002:B,2003:C,2004:D E Jan:1to Sep:9, Oct:O,Nov:N,Dec:D
] : 5 series is blank, 7 series is 7, 9 series is 9, 10 series is 10, 14 series is 14, 20 series is 20
n Packaging Specifications
Standard Part No. Packing Quantity and Taping Specification ERZVA5D111 ERZVA7D111 ERZVA9D111 (Straight Leads and Taped) ERZVA5V111 ERZVA7V111 ERZVA9V111 (Crimped Leads and Taped) ERZVGAD180 to 621 ERZVGAD681 to 112 (Straight Leads and Taped) ERZVEAV180 to 621 ERZVEAV681 to 112 (Crimped Leads and Taped) ERZVGED180 to 621 ERZVGED681 to 112 (Straight Leads and Taped) ERZVEEV180 to 621 ERZVEEV681 to 112 (Crimped Leads and Taped) Dimensions in mm (Packing Case)
1000 pcs./Box A B C 1000 pcs./Box 55 max. 330 max. 340 max.
1000 pcs./Box 500 pcs./Box 1000 pcs./Box 500 pcs./Box 500 pcs./Box 250 pcs./Box 500 pcs./Box 250 pcs./Box
A B C
65 max. 360 max. 340 max.
n Note l Missing components on tape in succession shall be 3 pcs max. and total packing quantity shall be same as indications on the box.
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Test Methods/Description Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to 35 C, relative humidity of maximum 85 % The voltage betwen two terminals with the specified measuring current CmA DC applied is called VC or VCmA. The measurement shall be made as fast as possible to avoid heat affection. The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied continuously. The maximum voltage between two terminals with the specified standard impulse current (8/20 s) illustrated below applied.
(%)
n Performance Characteristics
Characteristics Standard Test Condition Varistor Voltage Maximum Allowable Voltage Specifications NNN
Clamping Voltage
To meet the specified value. Rated Power Maximum Energy Maximum 2 times Peak Current (Withstanding Surge 1 time Current) Temperature Coefficient of Varistor Voltage Capacitance The power that can be applied in the specified ambient temperature. The maximum energy within the varistor voltage change of 10 % when a single impulse current of 2 ms or 10/1000 s is applied. The maximum current within the varistor voltage change of 10 % when a standard impulse current of 8/20 s is applied two times with an interval of 5 minutes. The maximum current within the varistor voltage change of 10 % with a single standard impulse current of 8/20 s is applied. VCmA at 85 C VCmA at 25 C 1 100 (%/ C) VCmA at 25 C 60 Capacitance shall be measured at 1 kHz 10 %, 1 Vrms max. (1 MHz 10 % below 100 pF), 0 V bias and 202 uC. The specified voltage shall be applied between both terminals of the specimen connected together and metal foil closely wrapped round its body for 1 minute. Classification (Nominal varistor voltage) V0.1 mA, V1 mA < 330 V V0.1 mA, V1 mA > 330 V Test Voltage (AC) 1000 Vrms 1500 Vrms No breakdown 0 to -0.05 %/uC max. To meet the specified value
Electrical
Withstanding Voltage (Body Insulation)
The change of VC shall be measured after the impulse current listed below is applied 10000 or 100000 times continuously with the interval of 10 seconds at room temperature.
Part No. ERZV05D180 to ERZV07D180 to ERZV09D180 to ERZV10D180 to ERZV14D180 to ERZV20D180 to ERZV05D820 to ERZV07D820 to ERZV09D820 to ERZV10D820 to ERZV10D182CS ERZV14D820 to ERZV14D112 ERZV14D182CS ERZV20D820 to ERZV20D112 ERZV20D182 Item Times Current ERZV05D680 ERZV07D680 ERZV09D680 ERZV10D680 ERZV14D680 ERZV20D680 ERZV05D471 ERZV07D511 ERZV09D511 ERZV10D112 Impulse Life (I) 104 Times Impulse 8 A (8/20 s) 25 A (8/20 s) 50 A (8/20 s) 50 A (8/20 s) 90 A (8/20 s) 130 A (8/20 s) 40 A (8/20 s) 100 A (8/20 s) 150 A (8/20 s) 150 A (8/20 s) 120 A (8/20 s) 200 A (8/20 s) 150 A (8/20 s) 250 A (8/20 s) 200 A (8/20 s) Impulse Life (II) 10 5 Times Current 5 A (8/20 s) 15 A (8/20 s) 35 A (8/20 s) 35 A (8/20 s) 50 A (8/20 s) 65 A (8/20 s) 25 A (8/20 s) 60 A (8/20 s) 85 A (8/20 s) 85 A (8/20 s) 75 A (8/20 s) 110 A (8/20 s) 90 A (8/20 s) 120 A (8/20 s) 100 A (8/20 s)
Impulse Life
AEVCmA/VCmA < 10 %
www..com
OZNRaO Transient/Surge Absorbers (Type D)
Test Methods After gradually applying the force specified below and keeping the unit fixed for 10 seconds, the terminal shall be visually examined for any damage. Terminal diameter Force f0.6 mm, f0.8 mm 9.8 N f1.0 mm 19.6 N The unit shall be secured with its terminal kept vertical and the force specified below shall be applied in the axial direction. The terminal shall gradually be bent by 90 in one direction, then 90 in the opposite direction, and again back to the original position. The damage of the terminal shall be visually examined. Terminal diameter Force f0.6 mm, f0.8 mm 4.9 N f1.0 mm 9.8 N After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be visually examined. After dipping the terminals to a depth of approximately 3 mm from the body in a soldering bath of 2355 uC for 20.5 seconds, the terminal shall be visually examined. After each lead shall be dipped into a solder bath having a temperature of 2605 uC to a point 2.0 to 2.5 mm from the body of the unit, using shielding board (t=1.5 mm), be held there for 101 s (5 series: 51 s) and then be stored at room temperature and normal humidity for 1 to 2 hours. The change of VCmA and mechanical damages shall be examined. The specimen shall be subjected to 1252 uC for 1000 hours in a thermostatic bath without load and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. Approximately 95 % of the termainals shall be covered with new solder uniformly. DVCmA/VCmA < 5 % No remarkable mechanical damage Specifications
n Performance Characterisitcs
Characteristics
Robustness of Terminations (Tensile)
Robustness of Terminations (Bending) Mechanical
No remarkable mechanical damage
Vibration
Solderability
Resistance to Soldering Heat
High Temperature Storage/ Dry Heat Humidity (Steady State)
DVCmA/VCmA < 5 %
The specimen shall be subjected to 402 uC, 90 to 95 % RH for 1000 hours without load and then stored at room temperature and normal hu- DVCmA/VCmA < 5 % midity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. The temperature cycle shown below shall be repeated five cycles and then stored at room temperature and normal humidity for 1 to 2 hours. The change of VCmA and mechanical damage shall be examined. Step Temperature (uC) Period (minutes) 1 403 303 2 Room temperature 153 3 1252 303 4 Room temperature 153
Environmental
Temperature Cycle
DVCmA/VCmA < 5 % No remarkable mechanical damage
High Temperature Load/ Dry Heat Load Damp Heat Load/ Humidity Load
After being continuously applied the Maximum Allowable Voltage at 852 uC for 1000 hours, the specimen shall be stored at room temDVCmA/VCmA < 10 % perature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. The specimen shall be subjected to 402 uC, 90 to 95 % RH and the Maximum Allowable Voltage for 1000 hours and then stored at room DVCmA/VCmA < 10 % temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. The specimen shall be subjected to 402 uC without load for 1000 hours and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. DVCmA/VCmA < 5 %
Low Temperature Storage/Cold


▲Up To Search▲   

 
Price & Availability of ERZV14DXXXC1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X